ListCodes Ngày 27022025 #1

ListCodes Ngày 27022025 #1 các sản phẩm được Power-Energy-Battery phân phối cũng chính là đại diện của hãng tại Việt Nam

ListCodes Ngày 27022025 #1
ListCodes Ngày 27022025 #1

Một số sản phẩm của ListCodes Ngày 27022025 #1

1.2 100% Finland Origin Vaisala Vietnam “INDIGO80 C0A0A1N0
Handheld Indicator
Power Supply Unit: UK AC-adapter, including USB-C cable
No Indicator
Connection Cables for Transmitters: M12-M8 Service Cable
No Connection Cables for Probes
Weatherproof Carrying Case for Indigo80 and HMP80 and DMP80 Series Probes  ASM214759″
1.2 100% Finland Origin Vaisala Vietnam “INDIGO80 C0A0ANN0
Handheld Indicator
Power Supply Unit: UK AC-adapter, including USB-C cable
No Indicator
Connection Cables for Transmitters: M12-M8 Service Cable
No Connection Cables for Probes
NO CARRYING CASE”
2 100% Finland Origin Vaisala Vietnam “HMP80 N1D1S0
Handheld Humidity and Temperature Probe
Probe (106 mm) with HUMICAP R2C Sensor
M12-M12 Probe Connection Cable  272075SP”
1 100% Finland Origin Vaisala Vietnam “DMT143 G1G2A1A3A0ASX
Miniature Dew Point Transmitter
Mechanical Connection: ISO G1/2″” Probe with DRYCAP®180D Sensor
Digital Output RS-485
Analog Signal output: 4…20 mA, 0 mA error state
Analog Output Scaling: -80…+20 °C Tda, ambient P
Alarm LED Setpoint: Off, only fault indication
Process gas air
1 bar Absolute
Cable 3.0 m (9.8 ft) with Open Leads  HMP50Z300SP
Standard sintered filter  DRW010335SP
Standard package for DMT143″
Codes heart
HM70F0A1A0DA
HM70F0B1A0EA
HM70F0C1A0AA
Equal heart
– HM70 F0A1A0DA đổi thành
INDIGO80 D0A0A1N0 và HMP80 L1A1S0
– HM70 F0B1A0EA đổi thành
INDIGO80 D0A0A1N0 và HMP80 L1A1S0
– HM70 F0C1A0AA đổi thành
INDIGO80 D0A0A1N0 và HMP80 L1C1S0

List code tiếp theo ListCodes Ngày 27022025 #1

heart heart
 RaytekJasScanner 100% USA/ Germany Origin (Raytek) Fluke Process Instrument Vietnam “TETTMP150P31R0
RAYTMP150P31R0
Infrared Linescanner – heart
 Raytek LineScanner / Fluke Sensor Temperature Scanner
100 to 350°C (212 to 662°F), 3.43 µm, Dworry
 75 : 1
RJ-45: Scanner data link is configured to plug into
any standard RJ45 Ethernet network socket
Standard configuration: 512 data points per scan line (up to 80Hz),
256 data points (up to 150Hz)”
heart pro#54  greystonejas#54
1 100% Mexico Origin GREYSTONE Vietnam “Model: DSD240
4 wire photoelectric duct mount smoke detector, 240 Vac”
2 100% Canada Origin GREYSTONE Vietnam “Model: CMD5B1000
Wall/Surface Mount Carbon Monoxide Detector, No Relay, No Communication”
3 100% Canada Origin GREYSTONE Vietnam “Model: CMD5B1000-010
Wall/Surface Mount Carbon Monoxide Detector, No Relay, 0-10Vdc out put”
heart 1 100% Canada Origin GREYSTONE Vietnam “Model: AVDTXX
Air flow transducer, 4 – 20 mA, 0 – 10 Vdc selectable outputs, 24 Vac/dc, 0 – 2 m/s (394.7 f/m), 0 – 10 m/s (1968.5 f/m) & 0 – 20 m/s (3937.0 f/m) – 0°C to 50°C (32°F to 122°F) temperature output”
2 100% Canada Origin GREYSTONE Vietnam “Model: AVDTXX
Air flow transducer, 4 – 20 mA, 0 – 10 Vdc selectable outputs, 24 Vac/dc, 0 – 2 m/s (394.7 f/m), 0 – 10 m/s (1968.5 f/m) & 0 – 20 m/s (3937.0 f/m) – 0°C to 50°C (32°F to 122°F) temperature output”
1 100% Canada Origin GREYSTONE Vietnam “Model: HSDTA324
Duct Humidity Transmitter, ABS enclosure with hinged and gasketed cover, 3%, 10,000 Ohm, Type 2, NTC Thermistor, +/-0.2°C”
1 100% Japan Origin Azbil Vietnam “Model: TY7043Z0P00
Description: Room Temperature Sensor”
1 100% EU Origin Delcon Vietnam “Model: SLI230CR
Relay”
2 100% EU Origin Delcon Vietnam “Model: SLI24CR
Relay”
3 100% EU Origin Delcon Vietnam “Model: MIS1GN
Socket”

List code tiếp theo ListCodes Ngày 27022025 #1

1 100% EU Origin Beckhoff  Vietnam “Code: CP2715-0010
Description:  Fanless multi-touch built-in Panel PC CP27xx-0010, 15-inch display 1024 x 768, multi-finger touch screen”
heart heart heart Sẵn kho 2pcs each giao ngay / StockSales / OnlineSales
heart heart 1 100% EU Origin EsaPyronics Vietnam “Art No: 74903
UV-2 UV SCANNER + BRACKET CHLG 3/4″”
Bulletin : E7001 DWG 74903-05″
2 100% EU Origin EsaPyronics Vietnam “Art No: 24754
SHUTTER UV-2 SHR DN20 230Vac G3/4″”
Bulletin : E7003 DWG 24754-00″
1 100% EU Origin EsaPyronics Vietnam “Art No: 24754
SHUTTER UV-2 SHR DN20 230Vac G3/4″”
Bulletin : E7003 DWG 24754-00″
1 100% EU Origin Pilz  Vietnam “Code:  774314
Description: PNOZ X3 110VAC 24VDC 3n/o 1n/c 1so
Safety relay”
2 100% EU Origin Pilz  Vietnam “Code:  774618
Description:  PNOZ XV3.1 300/24-240VACDC 3no 1nc 2no t
Safety relay”
1 100% EU Origin Pilz  Vietnam “Code:  774540
Description:  PNOZ XV3 30/24VDC 3n/o 2n/o t
Safety relay “
heart 1 100% Germany  Origin Ziehl-Abegg Vietnam “Code: FN071-SDK.6F.V7P1
Axial fan Axial fan with sickle blades with guard grille for short bell mouth
3~ 400V D/Y 50Hz P1 1,00/0,72kW
2,5/1,25A DI=0% 920/780rpm COSY 0,59 70°C
3~ 400V D/Y 60Hz P1 1,45/0,90kW
2,7/1,55A DI=0% 1030/770rpm COSY 0,77 70°C
3~ 460V D/Y 60Hz P1 1,55/1,05kW
2,8/1,6A DI=0% 1070/850rpm COSY 0,71 70°C
IP54 THCL 155
ErP conform 2015

List code tiếp theo ListCodes Ngày 27022025 #1

N=45,8
statA=39,1%
Terminal box K62
Mounted on Stator.
wiring diagram: 1360-108XA
Rating plate: 1x fixed
Fitting position H/Vu/Vo.
Motor protection: thermal contact
Operating mode: Continuous operation with occasional starts
according to DIN EN 60034-1:2011-02
Occasional starting between -40 °C and -25 °C is permissible
Continuous operation below -25 °C only with special bearings
for refrigeration applications on request”
Raytek Infrared LineScanner
1 100% USA/ Germany Origin (Raytek) Fluke Process Instrument Vietnam “RAYTMP150LTR0 Raytek Fluke Infrared LineScanner
Infrared Linescanner /  Infrared LineScanner Cement Application
20 to 350°C  (68 to 662°F), 3 to 5 µm, Dworry
 170 : 1
RJ-45: Scanner data link is configured to plug into any standard RJ45 Ethernet network socket
Standard configuration: 512 data points per scan line (up to 80Hz), 256 data points (up to 150Hz)”
heart heart 1 100% Korea Origin INHA ELECTRIC Blower  Vietnam “Part No.: IHB-402S
Ring blower”
1 “100% EU/China
Origin” “Rexroth
Vietnam” “PN: R912005982 FREQUENCY CONVERTER | R912005981 | Bosch Rexroth
Model: EFC5610-37K0-3P4-MDA-7P–NNNN-L1NN
Inverter”
heart heart cynjas
1 100% Korea Origin GASDNA Vietnam “Model: DI-20-2-2-1
Multi-Input Compact Indicator”
2.1 100% Korea Origin GASDNA Vietnam “Model: IR-22-1-M-1
Temperature measuring equipment
(Non – Contact Infrared Temperature)”
2.2 100% Korea Origin GASDNA Vietnam “Model: IR-22-2-M-1
Temperature measuring equipment
(Non – Contact Infrared Temperature)”
2.3 100% Korea Origin GASDNA Vietnam “Model: IR-22-1-M-1
Temperature measuring equipment
(Non – Contact Infrared Temperature)”

List code tiếp theo 

heart chkfu
1 100% EU Origin E+E ELEKTRONIK Vietnam “Model: EE03-M1C1
Humidity and Temperature Module
The names of the options have been changed for the
EE03 model. The model EE03-M1C1 we offer corresponds
to the specifications of your request. Pls check all details before order”
heart heart chkfu
1 100% Korea  Origin Kwangjin Vietnam “Code: KR2211-8A
Rotary joint”
1 100% EU Origin E+H Vietnam “Code: FTL31-AA4M3AAW5J
Description: FTL31-12Q2/0
Point level sensor”
heart heart chloejas
1 100% Italy   Origin Elettrotekkabel Vietnam “Code: 04110G40251A14
FLEXIDRUM TRACK CABLES T210 0,6/1 KV GREY RAL 7000 / BK NMBRD + Y/G 25gAWG14 (25g2.5 SQMM)”
heart kiejas chkfu
1 100% EU Origin Lenord Bauer  Vietnam “MODEL: GEL 260-UN008192D433
Encoder
2601 00000012801
with reference signal
Pulse number per revolution: 8192
Plug / cable output: 12-pole plug radial
Shaft diameter, length: d = 10 mm, L = 30 mm
Protection of the electronics: moisture- + vibration-proof
Temperature range: -20°…+85°C”
1FGH40K-1024G-90G-NG/20P Sn: 630584

List code tiếp theo ListCodes Ngày 27022025 #1

2 C-FGH6KK-2500G-90G-NG-S-J50/50P Sn:6224430
heart 1 100% EU Origin E+H Vietnam “Code: 5W3B40-BBEDBAEAFAAUD5K0AA2
Description: 5W3B40-3FC8/0
E+H electromagnetic flowmeter”
1 “100% EU/China
Origin” “Rexroth/Aventics
Vietnam” “PN: R901175657
Coil
Note : recheck STOCK khi order”
1 100% Germany  Origin Novotechnik  Vietnam “Code: TLH-1000
Linear Potentiometer Position Sensor Voltage Divider 1m 0.04% 10kOhm Clamp Mount Connector, 4-Pole IP40 TLH”
1 100% USA Origin Metrix Vietnam “5485C-008 Velocity Sensor
Velocity Sensor – 150 mV/ips, 2-PIN CONNECTOR”
1 100% EU Origin Hydac Vietnam “Model: HDA 4820-A-350-419
Pressure Transmitter
925363
Your requested type don’t exist anymore and
the successor is protected by oem.
We reqeusted the successor at the oem.
We can offer you alternative:
there is only the ‘standard data sheet’…
there is no data sheet for the HDA4820-A-350 with the modifications -417 or -419…
But I can give you this information:
Differences between 925363 and 925325: The transmitters are the same.
Only the scope of delivery is different
(925363 is only the transmitter while 925325 also has the cable socket enclosed).”
1 100% Germany Origin Werma Vietnam “Article no: 260.320.75
TMini TwinFLASH 24VAC/DC YE
Note: 212 replaced by 260″
“bắt buộc
2″ 100% Germany Origin Werma Vietnam “Article no: 260.700.01
Mini Adapter Floor Mount GY”
1 100% Germany Origin Werma Vietnam “Article no: 140.150.60
Multi-t.sounder WM 32 tne 115-230VAC RD”
2 100% Germany Origin Werma Vietnam “Article no: 140.150.60
Multi-t.sounder WM 32 tne 115-230VAC RD”
heart heart diajas 1 100% USA Origin Bulk Pro Systems Vietnam “Part No.: BPMS_4
Speed Sensor,1-3/4″” Magnetic Coupler, 4 PPR”
1 100% UK Origin    E2S Vietnam “Model:  BExBG05DPDC024AN2A1R/R
Description:
BExBG05D 5J 24Vdc
Entries: 2 x M20
Stopping plug/adaptor: Nickel Plated
Bracket/Guard (A4) 316 St/St
Product version: IECEx, ATEX, Ex EAC, INMETRO, PESO
Enclosure colour: Red
Lens colour: Red”

List code tiếp theo 

heart heart 1 100% EU Origin Keysight Vietnam “Model: DAQM900A
Data Acquisition System “
2 100% EU Origin Keysight Vietnam “Model: DAQ970A/C13SPWR-903
Data Acquisition System
DAQ970A – This item has been discontinued by the supplier
Above is the possible alternative, pls carefully check before order”
1 100% Japan Origin New-Cosmos Vietnam “Code : XO-326ⅡsA
Target Gas:O2
5M cable
Y51370000″
heart heart RaytekPro#30 RaytekJasScanner 100% USA/ Germany Origin (Raytek) Fluke Process Instrument Vietnam “TETTMP150P31R0
RAYTMP150P31R0
Infrared Linescanner
100 to 350°C (212 to 662°F), 3.43 µm, Dworry
 75 : 1
RJ-45: Scanner data link is configured to plug into
any standard RJ45 Ethernet network socket
Standard configuration: 512 data points per scan line (up to 80Hz),
256 data points (up to 150Hz)”

Để lại một bình luận

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *